York HD Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Nein York HD herunter. York HD User's Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 16
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
ADD - ON COILS
FOR USE WITH SPLIT-SYSTEM
COOLING & HEAT PUMPS
MODELS: MC, PC, FC, HD, HC, UC
600 - 2000 CFM 1.5 - 5 TON COILS
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.ariprimenet.org.
HORIZONTAL CASED
HC
FULL CASED
MULTI-POSITION
MC
UPFLOW
PARTIAL CASED
PC
HORIZONTAL
DUCT
HD
UPFLOW UNCASED
UC
UPFLOW/DOWNFLOW
FULL CASED
FC
ISO 9001
Certified Quality
Management System
258931-BTG-A-0606
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
TECHNICAL
GUIDE
TECHNICAL
GUIDE
DESCRIPTION
These cooling and heat pump coils are designed to be installed with
UPG furnaces and to be matched with UPG cooling and heat pump
outdoor units. All UPG coils utilize a TXV to provide our customers
with the optimum performance and refrigerant control required for
13+ SEER systems. Coils can be ordered with a R22 TXV factory
installed that can be easily converted to R410A by changing the bolt-
on TXV.
“Flex-coils” are also available without a factory installed metering
device. For added application flexibility a R22 or R410A TXV is
installed, on “Flex-coils”, in the field to meet your refrigerant choice.
Upflow/Downflow Coils Full Cased and Partial Cased
Coils –
Designed for high-efficiency to match any system, full cased
in the upflow or downflow and the partial cased in the upflow only
application
.
Multi-Position Coils -
Designed for high-efficiency like the
upflow/downflow coil but with the added flexibility that allows it to be
installed any position, upflow, downflow, horizontal right or left. This
coil can be easily applied to our furnace and modular air handler in
any configuration.
Horizontal Duct Coils -
Available for both cooling and heat pump
dedicated horizontal, slab coil, applications. Field transition may be
required
.
Dedicated Horizontal Cased Coils
These coils are cooling
only or heat pump approved for horizontal furnace or modular air
handler applications. Unlike the horizontal duct coils these cased
coils match the dimensions of the furnace or modular blower
.
FEATURES
Thermal Expansion Valve -
Provides flexibility to convert any
coil to R22 or R410A refrigerant. A true bolt-on TXV, valve assembly
and equalizer tube are bolt-on, no brazing required. TXV and sens-
ing bulb are mounted inside the cased coil cabinet. (Must be field
supplied for all “Flex-coils”)
MicroBlue™ Coated Fins -
All coils are treated with a
MicroBlue™ Hydrophilic coating to enhance the removal of conden-
sate during the refrigeration cycle and reduce the possibility of water
blow-off. The MicroBlue™ coating also reduces the growth of germ
causing microbes.
Insulated Cabinet -
All evaporator coil cabinets are thermally
insulated with foil faced insulation to prevent sweatin
g.
Internally Clean -
All evaporator coils are factory leak-tested,
dehydrated, sealed and shipped with a holding charge. The suction
and liquid lines are sealed with rubber plugs, no cutting of connection
stubs to attach line set
.
Durable Finish Inside and Out -
Coil casings are made of pre-
painted steel. The pre-treated flat galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep. All inter-
nal metal parts are made of G90 pre-painted steel i.e. triangular
plates, top plates, horizontal supports etc. (Coil header plates are
non-painted due to the brazing process during production.)
Optimum Heat Transfer -
Using the latest in heat transfer tech-
nology, staggered rows of copper tubes are mechanically expanded
into aluminum fins to provide optimum air to surface contact for
ample moisture removal as well as high performance ratings.
ACCESSORIES
Refer to Price Manual for specific model numbers.
TXV Kits -
Thermal expansion valve kits are available for “Flex-coil”
applications and converting R22 to R410A refrigerant or as a service
replacement. All TXV kits are non-braze
,
all connections are bolt-on
including the valve assembly and equalizer tube. (No orifice or any
other metering device is to used in conjunction with the TXV).
Coil Casing Without Coil
Coil casings are available in each
width that can be installed with the furnace or modular air handler
during initial installation. This option is available to allow the installer
the flexibility to install the coil at a later date without duct modifica-
tions.
Seitenansicht 0
1 2 3 4 5 6 ... 15 16

Inhaltsverzeichnis

Seite 1 - TECHNICAL

ADD - ON COILSFOR USE WITH SPLIT-SYSTEMCOOLING & HEAT PUMPSMODELS: MC, PC, FC, HD, HC, UC600 - 2000 CFM 1.5 - 5 TON COILSDue to continuous pro

Seite 2 - COOLING CAPACITY - Coil Only

258931-BTG-A-060610 Unitary Products GroupFULL CASED “A” TYPE MULTI-POSITIONModel ApplicationRefrig.Conn.TypesFaceArea(Sq. Ft.)RowsDeepFinPerIn.Coil S

Seite 3 - COOLING CAPACITY - COIL ONLY

258931-BTG-A-0606Unitary Products Group 11DIMENSIONSCoil - MCDimensions - MC CoilsModel A B C DRefrigerantLine Size** Refrigerant line sizes may requi

Seite 4 - 4 Unitary Products Group

258931-BTG-A-060612 Unitary Products GroupCoil - PCDimensions - PC CoilsModel A B C DRefrigerantLine Size** Refrigerant line sizes may require larger

Seite 5 - APPLICATION LIMITATIONS

258931-BTG-A-0606Unitary Products Group 13COIL - HD1-3/4C5-5/8BAD3-3/42-5/81-3/8VAPORCONN.LIQUIDCONN.3/4 MPTSECONDARYDRAIN CONN.3/4 MPTPRIMARYDRAIN CO

Seite 6 - HORIZONTAL - DUCT TYPE

258931-BTG-A-060614 Unitary Products GroupNOTES

Seite 7 - Unitary Products Group 7

258931-BTG-A-0606Unitary Products Group 15NOTES

Seite 8 - PHYSICAL DATA

Subject to change without notice. Printed in U.S.A. 258931-BTG-A-0606Copyright © by York International Corp. 2006. All rights reserved. Supersedes

Seite 9 - UNCASED UPFLOW - “A” TYPE

258931-BTG-A-06062 Unitary Products GroupCOOLING CAPACITY - Coil Only*ModelRatedCFMEnteringAir °F (Wet Bulb)MBH @ Evaporator Temperature and Correspon

Seite 10 - HORIZONTAL CASED TYPE

258931-BTG-A-0606Unitary Products Group 3COOLING CAPACITY - COIL ONLY*Model Coil Rated CFMEntering Air °F (Wet Bulb)MBH@ Evaporator Temperature and Co

Seite 11 - DIMENSIONS

258931-BTG-A-06064 Unitary Products GroupNotes:• MC coils available with a factory installed horizontal drain pan option (H).COOLING CAPACITY - Coil O

Seite 12 - (Opening)

258931-BTG-A-0606Unitary Products Group 5NOTE:Do not exceed minimum/maximum CFM limits shown under Air Flow Data.APPLICATION LIMITATIONSThese units

Seite 13

258931-BTG-A-06066 Unitary Products GroupSTATIC PRESSURE VS. AIRFLOW (BASED ON WET COIL)UPFLOW CASED "A" TYPEModel Airflow Wet CoilFC18APC18

Seite 14 - 14 Unitary Products Group

258931-BTG-A-0606Unitary Products Group 7CASED "A" TYPE MULTI-POSITIONModel Airflow Wet CoilMC18A600 0.22800 0.291000 0.36MC18B600 0.20800 0

Seite 15 - Unitary Products Group 15

258931-BTG-A-06068 Unitary Products GroupPHYSICAL DATACASED (FC) AND PARTIAL CASED (PC) UPFLOW “A” TYPEModel ApplicationRefrig.Conn.TypesFaceArea(Sq.

Seite 16 - Unitary 5005 Norman

258931-BTG-A-0606Unitary Products Group 9HORIZONTAL - DUCT TYPEModel ApplicationRefrig.Conn.TypesFaceArea(Sq. Ft.)RowsDeepFinPerIn.Coil SizeTubeGeomet

Kommentare zu diesen Handbüchern

Keine Kommentare