501562-UIM-A-0909R-410AOUTDOOR SPLIT-SYSTEM AIR CONDITIONINGMODELS: 18 SEER - CZH / AC8B / AL8B SERIES2 TO 5 TONSINSTALLATION MANUALLISTEDISO 9001Cert
501562-UIM-A-090910 Johnson Controls Unitary Products FIGURE 12: Thermostat Chart - Two Stage AC – Variable Speed FurnacesAC 26A Two Stage Air Condit
501562-UIM-A-0909Johnson Controls Unitary Products 11 FIGURE 13: Thermostat Chart - Two Stage AC – Variable Speed FurnacesAC 26B Two Stage Air Condit
501562-UIM-A-090912 Johnson Controls Unitary Products FIGURE 14: Thermostat Chart - Two Stage AC – Variable Speed FurnacesAC 31A Two Stage Air Condit
501562-UIM-A-0909Johnson Controls Unitary Products 13 FIGURE 15: Thermostat Chart - Two Stage AC – Variable Speed FurnacesAC 31B Two Stage Air Condit
501562-UIM-A-090914 Johnson Controls Unitary ProductsDEHUMIDIFICATION CONTROLA dehumidification control accessory 2HU06700124 may be used withvariable
501562-UIM-A-0909Johnson Controls Unitary Products 15SECTION VIII: INSTRUCTING THE OWNERAssist owner with processing warranty cards and/or online regi
501562-UIM-A-090916 Johnson Controls Unitary ProductsLED DIAGNOSTIC INDICATORSThe control includes two LED’s that display diagnostic information.LED1
501562-UIM-A-0909Johnson Controls Unitary Products 17FAULT CODE DISPLAYThe control will display any fault code that is currently active using theLED’s
501562-UIM-A-090918 Johnson Controls Unitary ProductsCOOLING OPERATIONFirst-Stage Cooling OperationDuring first-stage cooling operation, the control w
501562-UIM-A-0909Johnson Controls Unitary Products 19SECTION IX: WIRING DIAGRAM FIGURE 16: Wiring Diagram
501562-UIM-A-09092 Johnson Controls Unitary ProductsINSPECTIONAs soon as a unit is received, it should be inspected for possible dam-age during transi
Subject to change without notice. Published in U.S.A. 501562-UIM-A-0909Copyright © 2009 by Johnson Controls, Inc. All rights reserved. Supersedes: 347
501562-UIM-A-0909Johnson Controls Unitary Products 3GROUND INSTALLATIONThe unit may be installed at ground level on a solid base that will notshift or
501562-UIM-A-09094 Johnson Controls Unitary Products4. The vapor line must be insulated with a minimum of 1/2" foam rub-ber insulation (Armaflex
501562-UIM-A-0909Johnson Controls Unitary Products 56. Protect the vapor valve with a wet rag and braze the vapor line con-nection to the outdoor unit
501562-UIM-A-09096 Johnson Controls Unitary ProductsFIELD CONNECTIONS POWER WIRING1. Install the proper size weatherproof disconnect switch outdoors a
501562-UIM-A-0909Johnson Controls Unitary Products 7CFM SELECTION BOARD SETTINGSFor proper system operation the CFM Selection Board jumpers must beset
501562-UIM-A-09098 Johnson Controls Unitary ProductsFor additional connection diagrams for all UPG equipment refer to “Low Voltage System Wiring” docu
501562-UIM-A-0909Johnson Controls Unitary Products 9 FIGURE 11: Thermostat Chart - Two Stage AC – Two Stage Variable Speed FurnacesAC 24B Two Stage A